Programmable Constant Temperature and Humidity environment chamber /Testing chamber/ testing machine
standard It's according to IEC61215, IEC61646 etc standard
purpose It's to determine the ability of module to withstand the effects of long-term penetration of humidity
procedure The following severities are applied
1.Test temperature 85±2oC
2.Relative humidtiy 85±5%
3.Test duration 1000hh+48h
Final measurements After a recovery time of between 2h and 4h at 23±5oC and a relative humidity less than 75% under open-circuit conditions
Products image show