product feature -resistance measure up to 20mΩ with continuity detection -voltege measurement -manual power off -low battery indication -backlight
product image
Specifications
Model
MY8231S
Range
Resolution
Accuracy
DC voltage
2V/20V/200V
0.001V/0.01V/0.1V
±(0.5%+3)
600V
1V
±(0.8%+5)
AC voltage
2V/20V/200V
0.001V/0.01V/0.1V
±(0.8%+3)
600V
1V
±(1.0%+5)
DC current
20mA/200mA
0.01mA/0.1mA
±(1.8%+5)
AC current
20mA/200mA
0.01mA/0.1mA
±(2.0%+5)
Resistance
200Ω/2KΩ/20KΩ/200KΩ/2MΩ
0.1Ω/0.0001KΩ/0.1KΩ/0.1Ω/0.001MΩ
±(2.0%+5)
20MΩ
0.01MΩ
±(2.0%+5)
Capacitance
20nF
0.01nF
±(10%+40)
200nF/2uF/20uF/200uF
0.1nF/1nF/10nF/100nF
±(2.5%+20)
2000uF
1uF
±(5%+10)
Diode
√
On / off buzzer
√
Zero / Firewire Identification
√
Backlight
√
Floodlight
√
NCV
√
Power supply
2×1.5V AAA
Weight
150g
Size
130mm×62mm×27mm
Safety level
EN61010-1,-2-030,EN61010-2-033,
EN613261,CAT.III 600V
Matters needing attention
Do not use the instrument around explosive gas or steam or in humid environment
Do not use a damaged stylus. check whether the insulating layer of the stylus is damaged, whether there is metal leakage or signs of wear. check the on-off property of the stylus
When measuring, please connect the neutral line or ground line before connecting the live line. Please cut off the live wire before disconnecting, and disconnect the neutral wire and the ground wire.
When measuring, please hold your finger behind the stylus protector.
Before opening the back cover of the instrument, disconnect the probe from the object to be measured.
Do not use the meter in an environment that exceeds the CAT rating of the lowest rated single component in the meter, probe or accessory.